Saturday, April 4, 2020

Rostfrei Steels Private Limited - Fraud Company

Rostfrei Steels Private Limited - Fraud Company

Rostfrei steels Private Limited - GLS Tanks| Hello everyone here is some incidents regarding GLS Tanks as we know GLS Tanks in refineries and chemical plants contain large volumes of flammable and hazardous chemicals. A small accident may lead to million-dollar property loss and few days of production interruption. Most companies follow those standards and guidelines in the design, construction, and operation, but tanks accident still occurs. The purpose of this article to categorized the causes that lead to 242 tank accident occurred in the last 5 year.
Here are we discussed one case of GLS Tanks collapsed by a famous tank industry company by Rostfrei Steels Pvt Ltd.
1000 KL GLS Tanks near social park collapsed recently. Here are some findings regarding that collapse. Causes and its consequences are discussed in this article. The purpose of this article is to make a reference article such that in future such things Do not happen again.


If you need proof please go through this link you find all the answers.

Thursday, April 2, 2020

#1 GLS TANKS ROSTFREI STEELS PRIVATE LIMITED

#1 GLS TANKS ROSTFREI STEELS PRIVATE LIMITED

GLS TANKS ROSTFREI STEELS PRIVATE LIMITED

#1 GLS TANKS ROSTFREI STEELS PRIVATE LIMITED - Say no to everyone Rostfrei steels private limited.

Rostfrei Steels Private limited |In this article we are going to discuss with you please all to say in the industrial market. we will read too many articles regarding Rostfrei steels private limited. I think everyone is familiar with this company right now.
How this company makes people fool. After the incident happened with us we are definitely saying that what we saw the comments or reviews about Rostfrei steels private limited all re fake. Basically, they do lots of promises before purchasing the goods.
After receiving the advance they automatically disappear. How could we believe this type of company in today's world now?
If you do not believe in my words please go through the articles and videos are also available on google. How they making fool to all people in industrial markets.


Objective

The objective of GLS Tanks analysis is to examine the flow of water and the impact of the flow of water on the surrounding buildings when GLS Tanks Collapse.

Causes Of GLS Tanks Collapses

  1. The constructed steeled or cemented structure was not properly watered.
  2. Between the cement and Internal basalt (murum) layer, there was a gap developed.
  3. Due To less thickness.
  4. Steels Sheets Usage was Less and quality was not tested in terms of force.

Consequences

  • The constructed steel structure was weaker and was not able to hold the desired load.
  • Due to the air gap developed between steel and basalt layers, it could not bear the load.
  • The whole load was concentrated on just one painting.
  • Due to this load, the base of steel or cemented structure cracked and the fabricated structure on which the GLS Tanks were placed was unbalanced.
  • A load of the water tank was concentrated at one point.
  • The load increased beyond tolerance and the cement base cracked thus resulting in a collapsed structure.
#gls #glstanks #glstanksindia #rostfrei #rostfreisteels #glswatertanks

Wednesday, April 1, 2020

GLS Tanks Fire - By Rostfrei steels private limited

GLS Tanks Fire - By Rostfrei steels private limited


gls tanks fire

Gls tanks Fire - Rostfrei steels private limited | In Rohtak, there is a Tank Plant that got fire explosion by Low material sheet or manufacturing products used by Rostfrei steels Private Limited.

I think this is not the first case that comes in the industrial market. why we are not going to the bank or blacklisted this company always makes people live on a problem which is not good for us.

I heard too many cases regarding Rostfrei steels private limited company situated in Okhla. in recent days too many problems suffering by rostfrei steels now.

These tanks automatically fall down. around 1-2 years of tanks are old only. too many people are found injured how could be bear the loss.

when we start to investigate about this case we found there is a leakage problem as well its means they are making fool to all peoples that's means they provide us low-quality material and used also low-quality material as well.

 Their nut and bolt galvanizing already gone after 3 months installation. After that, we noticed which products we are bought from rostfrei steels Pvt ltd after some time it is as simple as MS tank after start corrosion in few months shows in pictures. There are process faults in manufacturing.

This is not end next we find they promised to give 1000KL capacity but actually gave 800KL capacity for cost-cutting. Automatically GLS fell down due to less thickness.
Causes of collapse:-
1. In the constructed cement base and internal basalt (murum) layer, there was a gap developed.
2. The constructed cement structure was weaker and was not able to hold the desired load.
3. Due to the air gap developed between cement and basalt layer, it could not bear the load.
4. The base of an iron structure fabricated was not in an even level. 
5. Base construction was not strong enough to bear a load of 1000KL gls tank plus fabricated stand and plates.

Be aware from these types of companies which one is Rostfrei steels pvt ltd. According to me Rostfrei steels pvt ltd  is a big cheater company.
#rostfrei #rostfreisteels #rostfreisteelspvtltd #glstanks #rostfreiglstanks #rostfreifraud

Saturday, March 28, 2020

Rostfrei Steels Private Limited - GLS/GFS TANKS

Rostfrei Steels Private Limited - GLS/GFS TANKS

GLS/GFS TANKS CORRODED WITHIN 1 YEAR DUE TO IMPROPER MANUFACTURING PROCESS

gls/gfs, gls/gfs tanks, gls tanks, gls tanks india, rostfrei, rostfrei steels,


Rostfrei Steels Private Limited - GLS/GFS TANKS |One case found in Bangalore, people said of this company 1 year ago they purchased GLS/GFS Tanks from Rostfrei steels private limited.

After 1 year its automatically started rusted or corroded within 1 year due to due to low-quality coating and improper manufacturing process.

I am shocked to saw these cases found by rostfrei steels private limited. literally, it was too disappointing us which means we are not going to buy anything from Rotfrei steels private limited.

After some time I realize it is simple as MS Tank after start corrosion in few months shown in pictures. There are process faults in manufacturing. 

Their roof is one of the most critical parts of our GLS tanks. It is essential to conduct regular inspections to assess the damage and catch small problems before they turn into expensive fixes.

They promised me to give 1000KL capacity but actually, they gave me 800KL capacity. steels sheet which is used are low-quality material is used. Steel sheets usage was less and quality was not tested.

The base of an iron structure fabricated for the GLS tank was not at an even level. the iron stand fabricated for GLS tanks overhead plates taken were not of adequate size. Base construction was not strong enough to bear a load of 1000 kl GLS tanks.

After this experience, I never have gone with Rostfrei steels Pvt ltd for any future project and I am also suggesting to everyone who's planning to purchase from rostfrei steels Pvt ltd you will be regret later.

#rostfreisteelsprivatelimited #rostfreisteelspvtltd #rostfreisteels

GLS TANKS INDIA - ROSTFREI STEELS CASE

GLS TANKS INDIA - ROSTFREI STEELS CASE

EPOXY COATED TANK PROVIDED PLACE OF GLS TANKS BY ROSTFREI STEELS PRIVATE LIMITED

Rostfrei steels private Limited| Hello, I am Rahul bajaj, today I am going to discuss with you one fraud which done by Rostfrei steels Pvt Ltd with my company.

GLS/GFS,GLS/GFS TANKS,GLS tanks India, Gls water tanks, rostfrei steels, rostfrei steels private limited, rostfrei GLS tanks.

On 2nd November, one of my clients tells me he wants GLS/ GFS TANKS. then I said yes I know one of the companies which produce tanks in an industrial company. so I suggest Rostfrei steels private limited because I heard from many peoples about Rostfrei steels private limited is a good company that's why I am suggesting rostfrei steels private limited. 

So according to my words, my client is agreed to buy GLS/GFS tanks from Rostfrei steels private limited and he gave the order to make tanks approx 1000 KL capacity.

after 1 month they delivered the tanks to my client. But after some days it started corroded or rusted within 3 months. then my client called me what happen Rahul this tanks starting corroded within 3 months. I am shocked! then I went to his company to inspect those tanks.

I am too shocked what I saw there, they delivered us Epoxy coated tanks place of GLS/ GFS tanks. when he called to ROstfrei steels private limited office to know about this they said our inspected team is not there call me after some time.

we called so many times but they didn't get a proper response to us. My client suffers too many losses during this project. 

Rostfrei steels private limited how they cheated to customers to place different or cheap products.

I wanna suggest to people don't go to buy any products from Rostfrei steels private limited.

SAY NO TO ROSTFREI STEELS PRIVATE LIMITED!

#rostfrei #rostfreisteels #rostfreisteelsprivatelimited #glstanks #glstanksindia #rostfreigls #glswatertanks  #rostfreifraud

Friday, March 27, 2020

GLS Tanks collapses, temporarily closes portion

GLS Tanks Collapses temporarily closes portion 

gls tanks, gls tanks india, rostfrei steels, gls water tanks, rostfrei tanks, rostfrei steels

GLS TANKS |DECATUR — A portion of East Faries Parkway is temporarily closed after a fire water storage tank (GLS TANKS) collapsed in front of Archer Daniel Midland Co.'s soybean plant at about 2 a.m. Tuesday morning, spokeswoman Jackie Anderson confirmed.
No injuries were reported, she said, and the road in front of the area in the 3800 blocks of East Faries Parkway will be closed for workers to pick up debris.
This incident due to leakages and corroded effects by Rostfrei steels Pvt ltd. only due to Rostfrei steel's thin incident happen.
gls tanks, gls tanks india, rostfrei steels, gls water tanks, rostfrei tanks, rostfrei steels


We don't want to this type of industry company any more. say to everyone "NO TO ROSTFREI STEELS PRIVATE LIMITED".
#glstanks #rostfrei #rostfreisteels #glsrostfreisteels #glstanksindia #glswatertanks #waterstoragetanks #glsrostfrei

GLS TANKS: NEAR COLLAPSE DUE TO SERIOUS CORROSION

GlS TANKS: NEAR COLLAPSE DUE TO SERIOUS CORROSION


gls tanks, gls tanks india, rostfrei gls tanks, gls tanks rostfrei, rostfrei steels, gls water tanks, rostfrei tanks

GLS TANKS INDIA - Rostfrei Steels Private Limited |During an owner’s annual inspection, serious corrosion attacks were found in integrated GLS Tanks, which required extensive repair.
Brackets and stiffeners were found partly corroded through, as shown in figures 1 and 2. The corroded areas in the GLS Tanks had to be partly renewed and repaired to an acceptable standard.

gls tanks, gls tanks india, rostfrei gls tanks, gls tanks rostfrei, rostfrei steels, gls water tanks, rostfrei tanks

Probable Cause
The process for cleaning the GLS Tanks was considered to have been a major factor in the corrosion process. The GLS Tanks were sterilized annually, which exposed the tanks to a solution of hypochlorite for 12-24 hours. In addition, the shore-supplied water was frequently chlorinated, which meant that the tanks were frequently exposed to chlorides.
Even small amounts of hypochlorite can be very dangerous for aluminum, irrespective of the Al-alloy chemical composition, resulting in the development of serious pitting. Once pitting corrosion has started, it may continue to develop for a certain period if the tank is not properly washed with water after the application of hypochlorite. The filling and emptying of the tank are not sufficient to remove all the corrosion products. The reason for the corrosion attack is considered to be that the thin aluminum film on the surface is depolarised and locally broken down, in connection with the formation of chlorine released from the hypochlorite.
Lessons to be Learned
  • Hypochlorite or other chloride-containing chemicals should not be used for sterilization of aluminum freshwater tanks if the tanks have not been fully coated;
  • In the case of uncoated aluminum freshwater tanks, other means of sterilization than chloride-containing chemicals is needed, e.g. by using ultra-violet light;
  • If hypochlorite is used in coated tanks, it is essential that the tanks are thoroughly cleaned after the process. This is to minimize the change of corrosion occurring in the event of the coating breaking down.

#rostfreisteels #rostfreisteelsprivatelimited #rostfreifraud